NOTES
Should eventually become part of blue prints and/or contract.
- General
- No steps anywhere!
- All doors 3' 0" unless specified otherwise. (except closets: see plans)
- In some places casings will be abbreviated or modified to fit.
- All doors with handles rather than knobs. (except closets: see plans)
- Electrical
- Wall switches 6" lower than normal
- Service (breaker) panel(s) to be mounted low enough for wheelchair use.
- Wire specified circuits to emergency sub-panel for future generator.
- See schedule of circuits to be supported by generator
- Plumbing
- Main water cutoff to be wheelchair accessible
- Kitchen
- All electric even if natural gas available
- Range is extra low
- Oven is quite low
- Counter heights vary, see plans
- Some counters open underneath as specified.
- Sink to raise and lower electrically
- See manufacturer: ?????
- Garage
- garage door must be at least 8' high for van access
- Laundry
- Front loading and front control appliances will be used
- No doors to utility area but jambs and casings for possible future doors?
- Utilities
- General
- Place units in garage rather than crawl space where possible
- Furnace
- Natural gas is possible,
- Heat pump if not
- Hot water
- Natural gas if possible
- Electric if not
- If natural gas used, cutoff valve to be wheelchair accessible
- Fire Place
- Direct vent gas
- Natural gas if available
- Propane otherwise
- Bath rooms
- Note special clearance requirements next to toilets; follow plans carefully
- If floor joist in way, cut and brace in consultation with framing contractor!